Teledyne-lecroy Serial Data Debug Solutions Manuale Utente Pagina 142

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 204
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 141
Serial Data Debug Solutions
919586 RevA
BRIEF HS COMMON MODE TEST DESCRIPTIONS
With HS Common Mode selected in the Category field, the following Measure values are available:
VCMTX-DATA-1, VCMTX-DATA-0, VCMTX-CLK-1, VCMTX-CLK-0, dVCMTXLF-DATA, dVCMTXHF-DATA,
dVCMTXLF-CLK, and dVCMTXHF-CLK.
Name
Purpose
VCMTX-DATA-
1
To verify that the Static Common-Mode Voltages (VCMTX(1), and VCMTX(0)) of the DUT Data &
Clock Lanes HS transmitter are within the conformance limits.
VCMTX-DATA-
0
VCMTX-CLK-1
VCMTX-CLK-0
dVCMTXLF-
DATA
To verify that the AC Common-Mode Signal Level Variations between 50 and 450MHz
(ΔVCMTX(LF)) of the DUT Data & Clock Lanes HS transmitter are less than the maximum
allowable limit.
dVCMTXLF-
CLK
dVCMTXHF-
DATA
To verify that the AC Common-Mode Signal Level Variations above 450MHz (ΔVCMTX(HF)) of the
DUT Data & Clock Lanes HS transmitter are less than the maximum allowable limit.
dVCMTXHF-
CLK
BRIEF HS LEVELS TEST DESCRIPTIONS
With HS Levels selected in the Category field, the following Measure values are available:
VOD-DATA-1, VOD-DATA-0, VOD-CLK-1, VOD-CLK-0, VOHHS-Dp, VOHHS-Dn, VOHHS-CLKp, and VOHHS-
CLKn.
Name
Purpose
VOD-DATA-1
To verify that the Differential Voltages (VOD(0) and VOD(1)) of the DUT Data & Clock
Lanes HS transmitter are within the conformance limits.
VOD-DATA-0
VOD-CLK-1
VOD-CLK-0
VOHHS-Dp
To verify that the Single-Ended Output High Voltages (VOHHS(DP) and VOHHS(DN)) of the
DUT Data & Clock Lanes HS transmitter are less than the maximum conformance limit.
VOHHS-Dn
VOHHS-CLKp
VOHHS-CLKn