Figure 14 - Phy Link Rate Stability Test Results
In the Measure section:
P1 and P2 are used to calculate the min and the max of F2. These are the measured values for Tx
Min Phy Link Rate Stability (5.3.1) and Tx Max Phy Link Rate Stability (5.3.1). These
values must be between +/- 100ppm in order to pass this test.
Tx 5.3.2 Common Mode RMS Voltage (CJTPAT)
The purpose of this test is to verify that the common-mode RMS voltage is within the specification limits.
After the completion of the Common Mode RMS Voltage test the oscilloscope is in the following
configuration:
Figure 15 - Oscilloscope Configuration after the Common Mode RMS Voltage Test
Shown on this screen
F2 is the Common Mode Trace. This is calculated by summing the two inputs and dividing by 2.
24 922545 Rev A