9.2 SendLevelOnly()
This function specifies that ONLY events of the specified transaction level should be sent to the
script.
Format : SendLevelOnly( level )
Parameters
level This parameter can be one of the values of the SendLevel() command
(see above).
Example
SendLevelOnly( _LINK ); # Send ONLY Link level events.
9.3 DontSendLevel()
This function specifies that events of the specified transaction level should NOT be sent to the
script.
Format : DontSendLevel( level )
Parameters
level This parameter can be one of the values of the SendLevel() command
(see above).
Example
DontSendLevel( _LINK ); # DO NOT send Link level events.