7.1.2 ISASAnalyzerErrors::get_Count
HRESULT get_Count(
[out, retval] long* number_of_errors );
Returns the number of errors in the trace.
Parameters
number_of_errors Number of elements in the collection
Remarks
Example
WSH:
' Makes recording and saves the portions of the recorded trace
' where "Running Disparity" errors occured.
CurrentDir = Left(WScript.ScriptFullName, InstrRev( WScript.ScriptFullName, “\” ))
Set Analyzer = WScript.CreateObject( “LeCroy.SASTracer” )
Set Trace = Analyzer.MakeRecording( CurrentDir & "Input\test_ro.rec" )
Set Errors = Trace.AnalyzerErrors( 32 ) ' Running Disparity Error
For Each ErrorPacketNumber In Errors
ErrorFile = CurrentDir & "\Output\PckLen_error_span_" &
CStr(ErrorPacketNumber) & ".sas"
Trace.Save ErrorFile, CInt(ErrorPacketNumber)-5, CInt(ErrorPacketNumber)+5
Next