File-based Decoding User Manual Chapter 11: Primitives
LeCroy Corporation 47
Complete()
Complete()
Parameter Meaning
Default
Value Comments
Support
Supported by Bluetooth and Firewire analyzers only.
Return value
An integer that should be passed back to the application unchanged.
Comments
This should be called when it has been decided that an input context has been accepted
in
to a transaction, and that the transaction is complete. The return value of this function
should be passed back to the application from the ProcessData function. This function
co
uld be used to associate the input context with the output context.
Example
if ( done )
return Complete();